The combination of platinum and titanium substrate is firm, the performance is stable,
the output current density is high, the loss is small, and the service life is long.
Substrate material: TA1
Electrode column: TA1
Electrode column connection method: butt welding, spot welding or screw fixing
Plating process: water plating/vacuum plating
Coating Composition: Platinum Pt
Precious metal coating thickness: 0.2-5 μm
Ambient temperature: ≤ 65℃
Use environment pH value: 2-12
Working current density: ≤ 2000A/m2
Coating characteristics: platinum and titanium substrates are firmly combined, with stable performance, high output current density, low loss and long life.
Product shape: net, plate, tube, rod, wire, etc, or special-shaped material
Advantages of coated titanium anode: strong corrosion resistance, long working life; DSA dimensionally stable, electrode does not dissolve; high current density, low working voltage; low energy consumption, high productivity; DSA light weight, can reduce labor intensity; Used repeatedly.
Test basis: "Water Electrolysis Machine CAS124-2007" "Metal Anode Coating of Electrolytic Cell HG/T2471-2011"
Test conditions: 0.5mol/ H2SO4 (GB 625); Temperature: (40±1)℃; Anode current density: 2.0A/cm2; Anode surface area: 1.0cm2; Plate spacing: 1.0 cm;
Links: